GPU 90

Specification Generator:

  • 400Hz 115/200 volts nominal, ±10% adjustable, 3 phase four wire system, Y connection.
  • Lagging power factor: 0.8, synchronous brushless, self-cooling
  • Permanently lubricated dual bearings, brushless rotating rectifier assembly, directly coupled to the engine.
  • Vibration absorber mounted on the trailer.

Electric system:

  • Transient voltage recovery time: 0.1 second (no load to rated load)
  • Transient surge voltage range: 90-140 V
  • Modulation: ≤ 3.5 V
  • Phase voltage displacement with balanced load: <120°± 2°
  • Crest factor: 1.31—1.51
  • Individual harmonic distortion: ≤3% of the fundamental voltage
  • Total harmonic distortion: ≤4% of the fundamental voltage
  • Voltage regulation: ≤113-117 V
  • Voltage adjust: ≤±12 V

Engine:

  • Cummins QSB 6.7, water cooled, TIER III, 6 cylinder, turbocharged
  • TCD 2013, water cooled Euro stage III, 6 cylinder, turbocharged
  • 24 V DC battery system, low oil pressure shutdown, intake air restriction indication
  • High coolant temperature shutdown
  • Electronic governor system
  • Vibration absorber

Overload:For enlargement please click! (POPUP opens)

  • 125% rated load for 5 minutes
  • 150% rated load for 10-18 seconds
  • 200% rated load for 3-5 seconds

Frequency:

  • Regulation: ±4 Hz steady rate
  • Modulation: ≤2 Hz
  • Transient recovery: ≤25 Hz/s

Protection

  • Over-voltage: instantaneous disconnect of load at 125±1 V in 2-4 seconds
  • Under-voltage: instantaneous disconnect of load at 100±2 V in 2-4 seconds
  • Over-frequency: disconnects output above 430 Hz in 1-3 seconds
  • Under-frequency: disconnects output below 370 Hz in 1-3 seconds

Trailer:

Type GPU 90 kVA / GPU 120 kVA
Tire size front
5.00-8
Tire size rear
6.5-10
Turning radius 3.600 mm
brakes tow bar activated, drum type
Gross weight
3000 kg
Dimension (LxWxH)
3.600 x 1.680 x 1.780 mm
Ground Clearance
190 mm

Performance:

Type GPU 90 kVA GPU 120 kVA
Capacity
90 kVA
120 kVA
Rated current
271 A
346 A
Power factor
0,8 0,8
Rated voltage
115 / 200 V
115 / 200 V
Rated frequency
400 Hz
400 Hz